Fan and thermic test-stand |
| |
|
| The unit is a combination of fan test
and heat transfer technics. Heat from circulating hot water is exchanged
to an air flow. This provides wide thermodynamical investigations:
- Radial fan characteristics
- Radial fan efficiencies
- Characteristics of a circulating pump
- Heat exchange efficiencies
Properties:
- Centrifugal 4-speed waterpump
- 3-kW electric heater with on/off control
- Iris air flow restrictor
|
| |
Measuring systems:
The measuring devices are digitally connected to the
internal controller, sending serial data to the comprised portable PC.
Stand control and data acquisition is performed by .
Measured quantities are:
- Torque and speed of the motor
- Water flow-rate
- Pressures
- Pitot static tube in the air duct for pressures and
flowrate measurement
|
| |
Technical details:
Dimensions: |
1.5m x 0.65m x 1.8m |
| Weight: |
180 kg |
| Electrical supply: |
230V AC |
|
|
| |
See also test-stand which is an extension of this unit. |
| |
 |
| |
| F |
Radial centrifugal fan |
| M |
Swivel bearing motor |
| HE |
Heat exchanger |
| I |
Iris orifice |
| P |
Pump |
| C |
Impulse generator flow |
| B |
Boiler |
| p |
Rotameter |
| V |
Manometer |
| Δp |
Differential manometer |
| 1-4 |
Temperature measurements |
| HC |
Heatflow calculator |
|
|
Keywords: Fan characteristics,
circulation pump characteristics |
| |
 |
| ©TeLC Unna 2004 |